close

Anmelden

Neues Passwort anfordern?

Anmeldung mit OpenID

Joystick CHALLENGER Ji - Gecma

EinbettenHerunterladen
Betriebsanleitung
Joystick
CHALLENGER Ji
MANUAL JI REV 1.6 DE.DOC 31.01.07
A.J.
1
Inhaltsverzeichnis
Inhaltsverzeichnis.................................................................................................2
Einleitung.............................................................................................................2
Ausführungsvarianten des Challenger Ji .............................................................2
Technische Daten...............................................................................................4
Montage.............................................................................................................3
Anschlussbelegung.............................................................................................3
Sicherheitshinweise..............................................................................................5
Allgemeine Hinweise...........................................................................................6
Einleitung
Der Challenger Joystick (Ji) ist ein eigensicherer Joystick zum Einsatz in Zone 0 / Zone 22.
Der Joystick arbeitet elektrisch kontaktlos, welches zu einem nahezu wartungs- und
verschleißfreien Betrieb ermöglicht. Durch die eingesetzte Sensorik ergibt sich eine praktisch
unendlich feine Auflösung.
Neben den Tastern in der Frontplatte kann ein Taster im Joystickgestänge integriert werden (z.B.
Ji-SW). Dieser Taster hat die selbe Funktion wie die linke Maustaste.
Er dient der Steuerung eines ASD (Application Supporting Devices) z.B. eines PC-Terminals und ist
für den Einsatz im explosionsgefährdeten Bereich ausgelegt.
Bei dem Einbau in Challenger-Komponenten muss am Challenger FMO (Display) die Option
„2.PD“ vorhanden sein.
Er besitzt eine PS/2-Datenschnittstelle zum Anschluss an eine eigensichere Datenschnittstelle.
Der CHALLENGER Ji ist eine Microsoft™-kompatibler Joystick und zu dem Standard-Microsoft™
Maustreiber kompatibel.
Ausführungsvarianten des Challenger Ji
Der Challenger Ji kann in verschiedenen Ausführungsvarianten geliefert werden:
Ji
Ji-B6
Ji-B12
Ji SW
Ji-B6 SW
Ji-B12 SW
Joystick
Joystick mit Barriere für max. 6,25V
Joystick mit Barriere für max. 12,5V
Joystick mit Switch
Joystick mit Barriere für max. 6,25V mit Switch
Joystick mit Barriere für max. 12,5V mit Switch
MANUAL JI REV 1.6 DE.DOC 05.01.04
2
Montage
Um die Gehäuseschutzart IP65 zu gewährleisten, muss das Joystickmodul in ein min. IP65
zertifiziertes Gehäuse (mit einem Ausschnitt von 153mm x 84mm bzw. 6“ x 3,3“) eingebaut
werden.
Das Joystickmodul wird mit der Frontseite nach außen in den Gehäuseausschnitt gesteckt
und mit Hilfe von mindesten vier gleichmäßig über den äußeren Joystickgehäuseumfang
verteilten Befestigungsklammern von innen so montiert, das dass Modul dicht aufliegt.
Der elektrische Anschluss ist dem Verdrahtungsplan #10100470 und der Zulassung zu
entnehmen.
Anschlussbelegung
Anschluss
Bedeutung
K44-1 bzw. braun bzw. 1
K44-2 bzw. weiß bzw. 2
K44-3 bzw. gelb bzw. 3
K44-4 bzw. grün bzw. 4
Speisestromkreis +UB
Speise-/Datenstromkreis GND
Data
Clock
Die Klemmennummerierung ist dem Klemmtypenschild zu entnehmen, welches
in Nähe der Klemme angebracht ist.
Details sind dem Verdrahtungsplan #10100470 und der Zulassung zu entnehmen.
MANUAL JI REV 1.6 DE.DOC 05.01.04
3
Technische Daten
Zone 0
Zone 1
Zone 22
II 1 G EEx ia IIB T4
II 2 G EEx ia IIC T4
II 3 D T60°C IP6X
Ex ia IIB T4
Ex ia IIC T4
Ex T60°C IP6X
Betriebstemperatur:
(10 bis 90% rel. Luftf., n. k.)
Ta: -20°C ... +60°C
(-4°F to 140°F)
Ta: -40°C ... +70°C
(-40°F to 158°F)
Ta: -25°C ... +60°C
(-13°F to 140°F)
Zulassung:
TÜV 04 ATEX 2459
TÜV 04 ATEX 2459
TÜV 04 ATEX 2647X
Gehäusematerial:
Stahlblech/Aluminium
Gehäuseabmessungen:
s. Zeichnungen
Gehäuseschutz:
Frontseitig IP65 bei sachgerechtem Einbau.
Anschluss Versorgung:
Klemme K44 2 x (0,5-2,5)mm² starr / flexibel
oder Anschlussleitung
Anschluss Schnittstelle:
Klemme K44 2 x (0,5-2,5)mm² starr / flexibel
oder Anschlussleitung
Lagertemperaturbereich:
-20 °C - +60°C (-4°F to 140°F), 10 bis 90% rel. Luftf., n. kond.
Zündschutzart:
Typ Ji:
Versorgungsspannung:
Durch eigensichere Versorgungseinheit mit den techn.Daten:
Umax ≤ 5,5 V, Imin > 14 mA
Cimax 19uF, Li vernachlässigbar
Typ Ji-B6:
Versorgungsspannung:
Durch eigensichere Versorgungseinheit mit den techn.Daten:
Umax ≤ 6,25 V, Imin > 14 mA
Ci, Li vernachlässigbar
Typ Ji-B12:
Versorgungsspannung:
Durch eigensichere Versorgungseinheit mit den techn.Daten:
Umax ≤ 12,5 V, Imin > 14 mA
Ci, Li vernachlässigbar
Techn. Daten Datenstromkreis alle Ji-Typen:
Durch eigensichere Schnittstelle mit den techn.Daten:
Uimax ≤ 5,5 V
Uo ≤ 5,5V, Io ≤ 142mA, Po ≤ 105mW
Ci, Li vernachlässigbar
Material Joystickgestängeschutz:
Neopren
Max. zulässige Belastung:
300N
Weitere Details sind der Zulassung zu entnehmen.
MANUAL JI REV 1.6 DE.DOC 05.01.04
4
Sicherheitshinweise
Allgemeine Sicherheitshinweise
Die in diesem Kapitel aufgeführten Hinweise sind konsequent zu beachten, um einen sicheren und
zuverlässigen Betrieb zu gewährleisten.
Die Zulassung mit den darin enthaltenen besonderen Bedingungen sind zu beachten.
Die nationalen Sicherheitsvorschriften, Unfallverhütungsvorschriften sind zu beachten.
Die Installation darf nur von Fachleuten ausgeführt werden. Diese Personen müssen sich mit den
Besonderheiten in explosionsgefährdeten Anlagen auskennen.
Fehlerhafter oder unzulässiger Einsatz sowie das Nichtbeachten der Hinweise dieser Betriebsanleitung
schließen eine Gewährleistung aus.
Verwenden Sie das Gerät nur für den zugelassenen Einsatzzweck.
Umbauten und Veränderungen am Gerät sind nicht zulässig.
Das Gehäuse darf ausschließlich von der Fa. Gecma Components GmbH geöffnet werden.
Montage
Die nationalen Montage- und Errichtungsvorschriften sind zu beachten.
Die allgemein anerkannten Regeln der Technik sind zu beachten.
Alle Betriebsmittel sind nach den geltenden Normen, Richtlinien und Installationsanweisungen richtig und
ordnungsgemäß anzuschließen und zu betreiben.
Das Gehäuse ist durch die Erdungsvorrichtung zu erden. Diese Erdung muss mit mindestens 4mm²
Aderquerschnitt erfolgen.
Das Gerät darf nur im spannungslosen Zustand angeschlossen werden.
Die Errichtung des eigensicheren Leitungszuges mit Versorgungs- und Signalleitungen muss so ausgeführt werden,
dass zwischen den einzelnen Stromkreisen kein Fehler in Betracht gezogen werden muss, siehe IEC 60079-14,
12.2.2.8.
Sollte bei einer Nutzung in einer Staubatmosphäre der Joystick ausgetauscht werden, muss das Gerät bzw.
Gehäuse in welches der Joystick eingebaut ist zuerst spannungslos geschaltet werden und ggf. den
Vorschriften entsprechend abkühlen. Bevor Sie das Gerät bzw. Gehäuse öffnen und während das Gerät
bzw. Gehäuse offen ist, muss die Umgebung des Gerät bzw. Gehäuse soweit staubfrei gehalten werden,
dass kein Staub ins Gehäuseinnere eindringen kann. Beim Einbau der neuen Komponenten ist darauf zu
achten, dass alle Dichtungen im einwandfreien Zustand sind und diese überall ordnungsgemäß
abdichten.
Bevor Sie das Gerät in Betrieb nehmen, stellen Sie sicher, dass das Gerät vorschriftsmäßig installiert wurde
und das Gerät und dessen Verkabelung nicht Beschädigt ist.
Wurde das Gerät nicht eigensicher gespeist, verliert es die Zulassung und darf nicht als eigensicheres
Gerät betrieben werden. Wurde das Gerät eigensicher mit niedrigem Schutzniveau betrieben (z.B. ib), darf
es danach nicht in Anwendungen für höheres Schutzniveau (z.B. ia) betrieben werden.
Betrieb
Das Gerät darf nur im unbeschädigten und sauberen Zustand betrieben werden.
Bei Beschädigungen jegliche Art, die den IP-Schutz beeinträchtigen könnten (z.B. Risse, Löcher oder
gebrochene Komponenten), muss das Gerät sofort außer Betrieb genommen werden. Für eine
Wiederinbetriebnahme müssen erst die defekten Komponenten ausgetauscht werden.
Bei Beschädigung des Joysticks darf dieser nicht weiter berührt werden, es besteht Verletzungsgefahr.
Sollte das Gerät in einer Staubatmosphäre genutzt werden, müssen Staubdicken >5mm entfernt werden.
MANUAL JI REV 1.6 DE.DOC 05.01.04
5
Bei Nichtbeachtung & Zuwiderhandlung kann der vorgeschriebene Explosionsschutz nicht garantiert
werden, bzw. besteht kein Anspruch auf Gewährleistung!
Abweichungen bedürfen einer schriftlichen Genehmigung der Fa. GeCma Components GmbH.
Allgemeine Hinweise
Bitte lesen Sie vor Beginn der Montage die ganze Bedienungsanleitung!
Im Zweifelsfall (in Form von Übersetzungsfehlern) gilt die deutsche Bedienungsanleitung.
Für Druckfehler und Irrtümer in dieser Bedienungsanleitung wird keine Haftung übernommen.
Wenn Sie Fragen oder Anregungen haben, wenden Sie sich bitte an:
GeCma Components GmbH
Heisenbergstraße 26 – 40
D-50169 Kerpen
Tel.: +49 (0)22 37 / 69 96 0
Fax: +49 (0)22 37 / 69 96 99
mailto:info@gecma.com
http://www.gecma.com
Technischer Fortschritt
Der Hersteller behält sich vor, technische Daten ohne spezielle Ankündigung dem
entwicklungstechnischen Fortschritt anzupassen.
Reparaturen, Gefahrenstoffe
Geräten, die zur Reparatur an die GeCma Components GmbH versendet werden, ist in jedem Fall eine
Fehlerbeschreibung beizulegen.
Folgende Maßnahmen müssen ergriffen werden, bevor Sie ein Gerät zur Reparatur einsenden:
Entfernen Sie alle anhaftenden Mediumreste. Beachten Sie dabei besonders Dichtungsnuten und Ritzen,
in denen Mediumreste haften können. Wir müssen Sie bitten, von einer Rücksendung abzusehen, wenn
es Ihnen nicht mit letzter Sicherheit möglich ist, gesundheitsgefährdende Stoffe vollständig zu entfernen.
Kosten, die aufgrund mangelhafter Reinigung des Gerätes für eine eventuelle Entsorgung oder für
Personenschäden (Verätzungen usw.) entstehen, werden dem Eigentümer des Gerätes in Rechnung
gestellt.
Verwendete Warenzeichen
AT, IBM und PS/2, sind eingetragene Warenzeichen der International Business Machines Corporation.
Microsoft, Windows und Windows NT sind eingetragene Warenzeichen der Microsoft Corporation.
Alle ansonsten im Text genannten und abgebildeten Warenzeichen sind Warenzeichen, der jeweiligen
Inhaber und werden als geschützt anerkannt.
MANUAL JI REV 1.6 DE.DOC 05.01.04
6
Translation
Translation
TÜV CERT
(13)
EC Design Test Certificate
(1)
(2)
Devices and safety systems for use in accordance with regulations in areas at risk from
explosion – guideline 94/9/EC
(3)
EC design test certificate number:
(14)
(15)
Description of the equipment:
Behind the front plate the electronic components are protected with a housing of at least IP 20.
The protection from front is IP65.
Is a higher enclosureprotection necessary the unit have to be mountet in a suitable hausing.
(4)
Device:
Challenger Joystick Typ Ji
(5)
Manufacturer: Gecma Components GmbH
(6)
Address:
(7)
The construction of this device and the different permitted version are specified in the
appendix to this design test certificate.
(8)
The TÜV NORD CERT GmbH & Co.KG, TÜV CERT certification agency, certifies - as
appointed office no. 0032 in accordance with the guideline of the council of the European
Community of 23rd March 1994 (94/9/EC) – the fulfilment of fundamental safety and health
requirements for the design and manufacture of devices and safety systems for correct use in
areas at risk from explosion, in accordance with Appendix II of the guideline.
The results of the test are set out in the confidential test report no. 04 YEX 551344.
The connection can be made via a premanufactured terminal strip or K44 connection. The
maximum cablelength is 50m. Refer following text.
In the frontplate can be mountet, beside the joysticklever, up to three buttons.
Heisenbergstr. 26-40
D 50169 Kerpen
The permitted ambient temperature range for each type can be found in the following table:
Category
1
2
The basic safety and health requirements are met by conformity with
EN 50014:1997 + A1 + A1 EN 50020:2002 EN 1127:1997 EN 50284:1999
(10)
If there is an “X” sign behind the certification number, special conditions for the safe use of the
device in the appendix to certificate are referred to.
(11)
This EC design test certificate only relates to the design and testing of the specified device in
accordance with guideline 94/9/EC. Further requirements of these guidelines apply for the
manufacturing and the bringing into circulation of this device. These requirements are not
covered by this certificate.
(12)
The marking of the device must contain the following information:
II 1 G EEx ia IIB T4 and
II 2 G EEx ib IIC T4, resp.
TÜV NORD CERT GmbH & Co. KG
TÜV CERT certification body
Am TÜV 1
D-30519 Hannover
Phone: 0511 986-1470
Fax: 0511-986-2555
EC Type Test Certificate No. TÜV 04 ATEX 2459
The Challenger Joystick (Ji) is an intriniscally safe operating device, e.g. for controlling a
pointer on a display.
TÜV 04 ATEX 2459
(9)
Annex
Hannover, 15.04.2004
sd./- illegible
The Head
This certificate must only be circulated without any modification.
Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG
Ambient Temperature Range
-20°C to 60°C
-40°C to 70°C
Electrical Data
Type Ji
Supply Current Circuit
(Terminals K44-1 or cable brown or 1;
K44-2 or cable white or 2)
In explosion protection type intrinsically
safety EEx ia IIC/IIB
Only for connection to certified intrinsically
safe circuits
Ui = 5.5 V
Uo = 5,5 V
Io = Ii of datacircuit but ” 77mA
Po= Pi of datacircuit but ” 105mW
Characteristic curve: linear
Ci = 19uF
The effective internal inductance are
negligibly small.
Interface circuit
(Data: Terminals K44-3 or cable yellow
or 3
Clock: Terminal K44-4 or cable green
or 4)
In explosion protection type intrinsically
safety EEx ia IIC/IIB
Only for connection to certified intrinsically
safe circuits
Ui = 5.5 V
Uo = 5,5 V
Io = 142mA (dynamic)
Io = Ii of supplycircuit but ” 50mA (static) each
circuit
Po = Pi of supplycircuit but ” 105mW
Characteristic curve: linear
Ci = 19uF
The effective internal inductance are
negligibly small.
This certificate must only be circulated without any modification.
Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG
Page 1 of 3
Page 2 of 3
Translation
Translation
Annex to EC Type Test Certificate No. TÜV 03 ATEX 2459
First Supplement
for
TÜV CERT
EC Design Test Certificate TÜV 04 ATEX 2459
Note the rules for connecting intrinsically safe circuits.
The intrinsically safe circuits are galvanic together connected.
Device:
The Challenger Joystick Typ Ji are suitable for mount and connecting to the under DMT 00
ATEX E 089 X with 1. supplement, certificatet devices Challenger KB, KB-2*, KMU, KMU-2*,
MTD, MTD-2* and under TÜV 03 ATEX 2251 certificatet devices KB-FPi and KB-2D-FPi
instead of Challenger TB and Challenger M.
Becouse of the protectionlevel and category of the in the top listed devices the protectionlevel
of the intrinsically safe circuits are “ib” and category 2 of the complete equipment.
The maximum permitted cablelength are 5m
(16)
The test documents are listed in test report no. 04 YEX 551344.
(17)
Particular requirement:
None
(18)
Fundamental safety and health requirements:
None in addition
Challenger Joystick Typ Ji, Ji-B6 and Ji-B12
Manufacturer: Gecma Components GmbH
Address:
Heisenbergstr. 26-40
D 50169 Kerpen
The Challenger Joystick type Ji will be expanded with the types Ji-B6 and Ji-B12
Additional the mechanical construction modified. Optional a button can be located to the
joysticklever.
Electrical Data
When use in category 1 G the circuits must be protected by
protectionlevel “ia”.
Type Ji
This certificate must only be circulated without any modification.
Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG
Supply Current Circuit
(Terminals K44-1 or cable brown or 1;
K44-2 or cable white or 2)
In explosion protection type intrinsically
safety EEx ia IIC/IIB
Only for connection to certified intrinsically
safe circuits
Ui = 5.5 V
Pi = 0,9 W
Uo = 5,5 V
Io = Ii of datacircuit but ≤ 77mA
Po= Pi of datacircuit but ≤ 105mW
Characteristic curve: linear
Ci = 19uF
The effective internal inductance are
negligibly small.
Interface circuit
(Data: Terminals K44-3 or cable yellow
or 3
Clock: Terminal K44-4 or cable green
or 4)
In explosion protection type intrinsically
safety EEx ia IIC/IIB
Only for connection to certified intrinsically
safe circuits
Ui = 5.5 V
Uo = 5,5 V
Io = Ii of supplycircuit but ≤ 77mA
Po = Pi of supplycircuit but ≤ 105mW
Characteristic curve: linear
The effective internal capacitances and
inductance are negligibly small.
This certificate must only be circulated without any modification.
Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG
Page 3 of 3
Page 1 of 3
Translation
Translation
Annex to 1. supplement of EC Type Test Certificate No. TÜV 03 ATEX 2459
Interface circuit
(Data: Terminals K44-3 or cable yellow
or 3
Clock: Terminal K44-4 or cable green
or 4)
Type Ji-B6
Supply Current Circuit
(Terminals K44-1 or cable brown or 1;
K44-2 or cable white or 2)
In explosion protection type intrinsically
safety EEx ia IIC/IIB
Only for connection to certified intrinsically
safe circuits
Ui = 6,25 V
Uo = 5,5 V
Io = 74 mA (short term)
Io = 38 mA (static)
Po= Pi of datacircuit but ≤ 53mW
Characteristic curve: linear
The effective internal capacitances and
inductance are negligibly small.
In explosion protection type intrinsically
safety EEx ia IIC/IIB
Only for connection to certified intrinsically
safe circuits
Ui = 5.5 V
Uo = 12,5 V
Io = 77 mA (short term)
Io = Ii of supplycircuit but ≤ 21mA (static)
Po = Pi of supplycircuit but ≤ 65mW
Characteristic curve: linear
The effective internal capacitances and
inductance are negligibly small.
Note the rules for connecting intrinsically safe circuits.
The intrinsically safe circuits are galvanic together connected.
Interface circuit
(Data: Terminals K44-3 or cable yellow
or 3
Clock: Terminal K44-4 or cable green
or 4)
In explosion protection type intrinsically
safety EEx ia IIC/IIB
Only for connection to certified intrinsically
safe circuits
Ui = 5.5 V
Uo = 6,25 V
Io = 77 mA (short term)
Io = Ii of supplycircuit but ≤ 43mA (static)
Po = Pi of supplycircuit but ≤ 67mW
Characteristic curve: linear
The effective internal capacitances and
inductance are negligibly small.
All other specifications valid without changes.
The test documents are listed in test report no. 04 YEX 551344-d.
TÜV NORD CERT GmbH & Co. KG
TÜV CERT certification body
Am TÜV 1
D-30519 Hannover
Phone: 0511 986-1470
Fax: 0511-986-2555
Hannover, 24.01.2006
sd./- illegible
The Head
Type Ji-B6
Supply Current Circuit
(Terminals K44-1 or cable brown or 1;
K44-2 or cable white or 2)
In explosion protection type intrinsically
safety EEx ia IIC/IIB
Only for connection to certified intrinsically
safe circuits
Ui = 12,5 V
Uo = 5,5 V
Io = 11 mA (short term)
Io = 9 mA (static)
Po= Pi of datacircuit but ≤ 15mW
Characteristic curve: linear
The effective internal capacitances and
inductance are negligibly small.
This certificate must only be circulated without any modification.
Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG
This certificate must only be circulated without any modification.
Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG
Page 2 of 3
Page 3 of 3
Translation
TÜV CERT
Declaration of conformity
(1)
(2)
Devices and safety systems for use in accordance with regulations in areas at risk from
explosion – guideline 94/9/EC
(3)
EC design test certificate number:
TÜV 04 ATEX 2647 X
(4)
Device:
Challenger Joystick Typ Ji, Ji-B6, Ji-B12
(5)
Manufacturer: Gecma Components GmbH
(6)
Address:
(7)
The construction of this device and the different permitted version are specified in the
appendix to this design test certificate.
(8)
The TÜV NORD CERT GmbH & Co.KG, TÜV CERT certification agency, certifies - as
appointed office no. 0032 in accordance with the guideline of the council of the European
Community of 23rd March 1994 (94/9/EC) – the fulfilment of fundamental safety and health
requirements for the design and manufacture of devices and safety systems for correct use in
areas at risk from explosion, in accordance with Appendix II of the guideline.
The results of the test are set out in the confidential test report no. 04 YEX 551344b.
(9)
The basic safety and health requirements are met by conformity with
Heisenbergstr. 26-40
D 50169 Kerpen
EN 50281-1-1: 1998 +A1 :2002
(10)
If there is an “X” sign behind the certification number, special conditions for the safe use of the
device in the appendix to certificate are referred to.
(11)
This EC design test certificate only relates to the design and testing of the specified device in
accordance with guideline 94/9/EC. Further requirements of these guidelines apply for the
manufacturing and the bringing into circulation of this device. These requirements are not
covered by this certificate.
(12)
The marking of the device must contain the following information:
II 3 D T60°C IP 6X
TÜV NORD CERT GmbH & Co. KG
TÜV CERT certification body
Am TÜV 1
D-30519 Hannover
Phone: 0511 986-1470
Fax: 0511-986-2555
Hannover, 29.10.2004
sd./- illegible
The Head
This certificate must only be circulated without any modification.
Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG
Page 1 of 2
Translation
(13)
First Supplement
for
TÜV CERT
Annex
(14)
(15)
Translation
EC Type Test Certificate No. TÜV 04 ATEX 2647 X
EC Design Test Certificate TÜV 04 ATEX 2647 X
Description of the equipment:
The Challenger Joystick (Ji) is an intriniscally safe operating device, e.g. for controlling a
pointer on a display.
Device:
The electrical connection realized with terminals or with a premounted cable, whereby the
electrical connection normally realized inside the additional enclosure.
Manufacturer: Gecma Components GmbH
In the frontplate can be mountet, beside the joysticklever, up to three buttons.
Address:
The operationtemperature specified to -25°C up to 6 0°C.
Challenger Joystick Typ Ji, Ji-B6 and Ji-B12
Heisenbergstr. 26-40
D 50169 Kerpen
Electrical Data
The Challenger Joystick type Ji, Ji-B6 and Ji-B12 will be produced regarding the new
productiondirectives.
Type Ji
The mechanical construction modified. Optional a button can be located to the joysticklever.
Supply Current Circuit
(Terminals K44-1 or cable brown or 1;
K44-2 or cable white or 2)
To connect to circuits with follow max. values
under normal conditions:
All other specifications valid without changes.
The test documents are listed in test report no. 04 YEX 551344-e.
U = 5,5V for type Ji
U = 6,25V for type Ji-B6
U= 12,5V for type Ji-B12
To connect to circuits with follow max. values
Interface circuit
(Data: Terminals K44-3 or cable yellow under normal conditions:
or 3
Clock: Terminal K44-4 or cable green U = 5,5V
or 4)
TÜV NORD CERT GmbH & Co. KG
TÜV CERT certification body
Am TÜV 1
D-30519 Hannover
Phone: 0511 986-1470
Fax: 0511-986-2555
(16)
The test documents are listed in test report no. 04 YEX 551344b.
(17)
Particular requirement:
The Challenger Joystick must be mounted into a enclosure which fulfill the requirements of
category 3D EN 50281-1-1 as minimum.
(18)
Fundamental safety and health requirements:
None in addition
Hannover, 24.01.2006
sd./- illegible
The Head
This certificate must only be circulated without any modification.
Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG
This certificate must only be circulated without any modification.
Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG
Page 2 of 2
Page 1 of 1
Document
Kategorie
Technik
Seitenansichten
11
Dateigröße
6 497 KB
Tags
1/--Seiten
melden